4.4 Test conditions. Unless otherwise specified (see 6.2), all tests shall be performed in
accordance with the test conditions specified in the applicable test method document or applicable
paragraph in this specification.
4.4.1 Standard atmospheric condition. Unless otherwise specified in this specification or the
applicable test method document, all tests shall be performed at ambient pressure altitude and
temperature.
4.4.2 Tapping. Unless otherwise specified in this specification, the indicator shall be tapped
before a test reading is taken.
4.4.3 Attitude. Unless otherwise specified in this specification or the applicable test method
document, the indicator shall be tested in the normal operating position.
4.5 Requirements cross reference matrix. Table IV provides a cross reference matrix of the
section 3 requirements tested or verified in the paragraphs below.
Table IV. Requirements cross-reference matrix
Requirement
Verification
Requirement
Verification
3.1
4.2
3.5.12
4.6.12
3.3
4.6.1, 4.6.2, 4.6.3
3.5.13
4.6.1
3.4.1
4.6.1
3.5.14
4.6.1, 4.6.13
3.4.2
4.6.1, 4.6.10
3.5.15
4.6.1, 4.6.11
3.4.3
4.6.24
3.5.16
4.6.14
3.4.4
4.6.1
3.5.17
4.6.15
3.4.5
4.6.1
3.5.18
4.6.1
3.5.1
4.6.4, 4.6.5, 4.6.6
3.5.19
4.6.1
3.5.2
4.6.1
3.6
4.6.1
3.5.3
4.6.7
3.7
4.6.1
3.5.4
4.6.4, 4.6.5, 4.6.6
3.8.1
4.6.16, 4.6.17
3.5.5
4.6.8
3.8.2.1
4.6.18
3.5.6
4.6.9
3.8.2.2
4.6.19
3.5.7
4.6.10
3.8.2.3
4.6.18
3.5.8
4.6.11
3.8.3
4.6.20
3.5.9
4.6.4
3.8.4
4.6.21
3.5.10
4.6.5
3.8.5
4.6.22
3.5.11
4.6.6
4.6 Tests.
4.6.1 Examination. The indicator shall be inspected to determine compliance with the
requirements specified herein with respect to materials, interface, markings, colors, weight,