MIL-PRF-83174E
Quantity of each type number
Number of items
First 10
1
Next 90
2
Each additional 100
2
4.4 Inspection conditions. Unless otherwise specified, all inspections shall be performed in
accordance with the test conditions specified in 4.4.1, 4.4.2, and 4.4.3.
4.4.1 Voltage input. The transmitter shall be tested with 28V dc power input.
4.4.2 Attitude. The transmitter shall be tested in its normal operating position.
4.4.3 Environmental tests. Prior to performing environmental tests, the transmitter shall be
operated under ambient conditions at the test site for baseline data.
4.5 Requirements cross-reference matrix. Table III provides a cross-reference matrix of section
3 requirements tested or verified in the paragraphs below.
TABLE III. Requirements cross-reference matrix.
REQUIREMENT
VERIFICATION
3.1
4.2
3.3
4.6.1
3.4
4.6.17
3.5
4.6.9, 4.6.10, 4.6.11, 4.6.14, 4.6.15
3.6.1
4.6.3, 4.6.5
3.6.2
4.6.3
3.6.3
4.6.3
3.6.4
4.6.18
3.6.5
4.6.1
3.6.6
4.6.1
3.6.7
4.6.3
3.6.8
4.6.13
3.6.9
4.6.4
3.6.10
4.6.3
3.6.11
4.6.6
3.6.12
4.6.8
3.6.13
4.6.12
3.6.14
4.6.3
3.6.15
4.6.1
3.6.16
4.6.2, 4.6.16
3.6.17
4.6.2